CATIA V5 KNOWLEDGEWARE PDF

For more information on the use of Knowledgeware throughout CATIA V5, see Using Knowledgeware Capabilities in the CATIA V5 Infrastructure User’s Guide. Catia V5 knowledgeware awareness session. Francois Trudel. DS Service, Lean Engineering. KBE Development Application Consultant. n. Product Lifecycle Management. 2. Value Proposition. 1. CATIA V5 Knowledgeware: What is it? Table Of Contents: CATIA V5 Knowledgeware. 3. Conclusion.

Author: Vilkis Shatilar
Country: Luxembourg
Language: English (Spanish)
Genre: Software
Published (Last): 17 March 2018
Pages: 166
PDF File Size: 13.68 Mb
ePub File Size: 18.89 Mb
ISBN: 838-9-97630-515-8
Downloads: 73037
Price: Free* [*Free Regsitration Required]
Uploader: JoJorr

A visual indicator located at the relations set level indicates that the set contains hidden relations. Select the relations set that you want to reorder in the specification tree. Quickly Accessing Parameters in the Formulas Editor. You can use this dialog box to measure the distance knowledgweare two edges for example.

If you want to have columns ordered in a given way f5 the design table, you must insert knowlrdgeware parameters one by one. A parameters set or a relations set can only be reordered in the same document.

Tips and Techniques – Summary This part is intended for those of you who need a quick answer to their questions about the Knowledgeware capabilities. Only parameters which are not already constrained by any other relation or by any other design table can be used to create a design table.

Displaying parameter values in the geometry area To display parameter values in the geometry area, you must have the Formulas Editor open. This capability does not apply to parameters such as booleans or strings. Similarly, select Operators to see basic mathematical and Boolean operators. You can also include a URL to a web page or a file that contains supporting information. The error message indicates that you must modify the entry or edit the range to create a valid entry.

  BLESTEMUL VRACIULUI PDF

In the Parameter properties tab, check Constant. The Filter Name and Filter Type filters can be used to restrict the display of a parameter kbowledgeware.

CATIA Knowledgeware Infrastructure

Note that if you try to delete a relations set containing another relations set with hidden relations, the message will be displayed. You can type the filtering relation directly in the appropriate field or click Edit Declaring a parameter as constant. To know more about working with parameters please see the About Parameters section.

Knodledgeware or modifying a formula. When the design table is knowledgewware, the rank of the columns fits the rank of the parameters in the Inserted parameters list.

The following Nonlinear Structural Analysis and Thermal Analysis boundary conditions, loads, and fields support the use of Knowledgeware:. For more information on propagation, see Propagation. Specify the file containing the design table data, then create the necessary associations. If you click the document root feature in the specification knowlesgeware, you display all the document parameters. When a formula links two parameters, and if the input parameter has a tolerance, this tolerance will not be propagated to the output parameter.

Second Method Click the icon in the Knowledge tool bar. Renamed parameters kmowledgeware published. Can be replaced with the same renamed parameter located in a part. To enter an argument value, position knowledgewate cursor where the argument is intended to be and capture the jnowledgeware definition from the specification tree or from the geometry area. If the imported parameters already exist in the document, the import process automatically updates the document.

Add range Specify limits for a parameter and indicate whether the limit values are included or excluded from the acceptable range. You can also add a comment to a parameter to indicate the reason for the Knowledgeware control.

  BARBARA FREETHY THE WAY BACK HOME PDF

Measure item Set a parameter equal to the measurement of a single entity. In the Value List window, enter the new values. It is possible to add ranges and default values to a design table.

You can use the Dictionary list to view the commands for a specific data type or function. U3 has a range of acceptable values knowledgsware using Add range ; there is no indication that this Knowledgeware technique is in use unless you enter a value that exceeds the allowable range.

If you specify x in the Filter Name field of the Select parameters to insert dialog box, you will display all the parameters with the letter x in their name xA, xB, xC, xD, xE. Check the Create a design table from a pre-existing file. In the Reorder window, select In or After and select a relation. You must unlock the field to edit the value.

Adding a comment to a parameter. If need be, rename this parameter.

Right-click it and select Relations. Click OK when done. Select the Part Number from the parameters list. Add a comment to indicate the reason for the limits applied to a parameter.

ENOVIAvpm-CATIA V5 Knowledgeware Integration

It is possible to add values to a single value parameter after creating it. Editing or modifying a parameter. The Knowledgeware options allow you to create formulas based on interdependent model values, specify a range or a list of acceptable values, and lock the current value of a parameter.

Note that it is also possible for you to proceed as follows: